10–33% OFFDecember Genomics Winter Fest: Save 10–33% on Next-Generation Sequencing Services! Book your December slot & lock in your discount!See pricing table

Collecting eDNA from water, soil, sediment and air

How to collect, filter and preserve environmental DNA samples for 16S amplicon, metabarcoding and shotgun metagenomics, with contamination controls.

1. Water

Collection

  • Grab sampling: collect a fixed volume (for example 5–8 L) into a sterile, DNA-free bottle. Use a depth sampler (for example Van Dorn) for deeper water.
  • Filtration (preferred): filter as soon as possible through a 0.22–0.45 µm membrane using a peristaltic pump, hand vacuum pump or syringe filter. Remove the filter with sterile forceps into a sterile 2 mL tube.
  • No filtration available: freeze the water directly at −20 to −80 °C.

Preservation

Keep filters in Longmire’s buffer, ethanol or RNAlater in the field, or freeze at −20 to −80 °C.

ProblemCauseSolution
ContaminationEquipment, bottles, human DNAGloves, sterile disposables, field blanks
DNA degradationSunlight, heat, delayFilter quickly; keep cold or in buffer
Clogged filtersTurbid water, algaePre-filter, use several filters or less volume
Low DNA yieldDilute or old samplesLarger volume; replicate samples

2. Soil and sediment

  • Wear sterile gloves and use clean, sterile scoops. Remove surface debris (leaves) and collect about 5–10 g from 0–10 cm depth.
  • Put into sterile tubes or Whirl-Pak bags. In variable sites, take several sub-samples and pool them.
  • Freeze at −20 or −80 °C as soon as possible, or use a soil preservation solution or silica gel in the field.
ProblemCauseSolution
PCR inhibitorsHumic acids, organic matterInhibitor-removal extraction kits
Cross-contaminationShared tools between sitesDisposable or sterilised tools
Uneven resultsSoil is patchyComposite samples and replicates
Degraded DNAHeat, microbial activityKeep cool; process quickly

3. Air (advanced)

  • Use an air sampler with HEPA or PTFE filters; volume depends on flow rate and time (for example 30 L/min for 30 minutes).
  • Store filters on dry ice or in preservative, then at −80 °C. Wear full protection (mask, gloves, hair net): airborne DNA is very low and easily contaminated.

4. Good practice for all eDNA samples

  • Controls: include a field or filtration blank (sterile water handled like a sample).
  • Change gloves between samples; sterilise reusable equipment with bleach or ethanol, or use disposables.
  • Replicates and records: collect replicates and note GPS, weather, time, temperature, pH and turbidity.
  • Transport: keep on ice or in a cool box until frozen; avoid freeze–thaw.
SourceMethodAmountStorage
WaterFiltration, 0.22–0.45 µm0.5–5 L−20 °C or buffer
SoilSterile scoop, tube5–10 g−80 °C or buffer
SedimentCore or scoop10 g or more−80 °C or buffer
AirHEPA / PTFE filterDepends on airflow−80 °C
Ready to start?

Have a sequencing project in mind?

Tell us your organism, sample type and what you want to find out. We will reply with the right service and a quote.

Or call +880 1308-222824